Common Signs of Water Booster Pump Failures

If you own or manage a taller building in New York City, it’s likely you have a water booster pump as part of your water distribution system. As with all pumps, there are times they malfunction or stop working altogether, which can create huge headaches for you when tenants don’t have adequate water pressure or potentially any water at all. Here are some common signs of water booster pump failures all property owners and managers should be aware of. When you know what to look for, you can react quickly and get the issue fixed right away.

Water Booster Pumps: The Basics

Equalizing pressure

Water booster pumps are installed in many New York City properties to equalize pressure between floors. The taller the building, the greater the pressure differential would be between stories without this type of pump to even out water distribution.

Water pumped from the ground level may not have sufficient pressure to reach the uppermost levels of the building. It might seem like installing a rooftop water storage system would remedy this, but the force of gravity means that, again, lower stories wind up receiving greater pressure. Therefore, even buildings with rooftop water tanks may need a water booster pump.

Smaller buildings may also require a water booster pump depending on their unique plumbing anatomy and construction. If you have checked for clogs, undersized pipes, and erroneously closed valves and still pressure is inadequate, you need the assistance of a booster pump.

NYC Plumbing Code

Chapter 6 of the New York City Plumbing Code determines minimum flow rates and pressure values for each type of fixture found in city properties. If the water pressure is not sufficient to meet these values, a pressure booster pump must be utilized. Booster pumps may not be shared between buildings, other than in projects with multiple buildings that share a common owner.

Signs of Water Booster Pump Failures

Pump won’t start

A water booster pump that won’t start is obviously malfunctioning. You may see various lights on the pump light up, depending on the model and what is happening with the system. Reasons for the pump failing to start include:

  • No power (check for a tripped breaker, wiring/connection problems, or outlet issues such as a tripped GFI)
  • Starting pressure is set too high or lower than incoming pressure
  • Needs to be reprimed
  • Filters need cleaning
  • Interrupted water supply
  • Defective motor
  • Broken or improperly adjusted pressure switches
  • Bound pump

You may be able to address some of these reasons on your own. If you’ve checked the power and wiring, reset pressure switches, reprimed as needed, cleaned filters, ascertained adequate water supply, and rotated the pump to unbind it without success, we’re happy to come out and take a look at it for you. We can replace or repair parts as needed, including the pump motor.

Pump not delivering water or delivering at reduced capacity

This is another clear sign of failure. There are multiple reasons for this as well. In addition to a lead-lag multi-pump system that’s not set up properly, it’s often due to a worn or dirty pump, which is why we advocate routine maintenance for all your water pumps at least once per year. Other causes include wiring or power issues as described above, foreign materials creating clogs, and discharge piping leaks.

Pump won’t stop

Most water booster pumps are not designed to work continuously, as they are often only needed during peak water demand times of the day. Therefore, your water booster pump should cycle on and off as needed. If the pump comes on but won’t stop, this is usually due to:

  • Problems with a lead-lag system setup
  • Leaks in end fixtures like toilets or water softeners
  • Pipe leaks
  • Jammed pump part, such as a piston
  • Leak in the pump housing
  • Bypass valve left open
  • Pressure settings need readjustment

Suction problems

Suction problems are some of the most common reasons why we are called in for service on water booster pumps. This can be related to the pump not working at capacity or there being no water produced at all. Here are some things you can check and possibly resolve yourself that may lead to water booster pump failures:

  • Clogged strainers (impede water flow and also harbor bacteria)
  • Trapped air in piping
  • Water softeners (pressure too low, softener too small, or installed before the water booster pump instead of after)
  • Filters not cleaned regularly
  • Shut-off valves fully closed or not opened enough, especially during high-demand periods

Pressure relief valve not working properly

Problems with a pressure relief valve may require professional service, but there are some instances where you may be able to resolve the issue yourself. It could be a problem with the mechanics of the valve itself, sometimes requiring replacement. However, if it’s merely air in the valve components, you may be able to bleed the air out and reset. Problems with pressure relief valves also sometimes point to issues with the pilot control valve or pressure relief check valve, which may require additional attention.

Outlet pressure too high or too low

Having pressure that’s too high or too low on the outlet (discharge) side of the pump can be undesirable, even if you are getting water. Check these things to see if you can adjust the pressure to the level you want:

  • Adjust the pressure relief valve in the direction you need.
  • Make sure the pressure relief valve can close (if the outlet pressure is too high).
  • Make sure the pressure relief valve can open (if the outlet pressure is too low).

The last two steps may involve disassembling the valve, clearing it of debris or scale, and making sure it functions properly. Otherwise, it needs replacement.

Pump making an excessive or unusual noise

A noisy pump may need better stability, especially if you can see it moving or vibrating too much. Make sure the mounting is sufficient, and if possible, reinforce the attachment. Noise may also be due to an insufficient water supply (possibly caused by suction issues, as described above), or it could be internal parts causing the problem, or the motor needs maintenance, such as lubrication, new bearings, or cleaning.

If you are having problems with a water booster pump in your building, the experts at Antler Pumps are here to help. We’re pros when it comes to dealing with the signs of water booster pump failures, and we are also familiar with complex pump systems, such as lead-lag pump setups. Call us at 212-534-2500 with your questions, or use our online form to schedule an appointment. Don’t wait until tenants in your building are left without water. Reach out today.


Article from

Our Privacy Policy

Antler Pump & Motor Corporation (the “Company”) strives to ensure the highest standards for property listings and customer information privacy. Please review the following statement to learn about our company practices and policies. Please be aware that our Privacy Policy is subject to change at any time.

1. Purpose.

This Privacy Policy (“the Policy”) provides information on how the Company uses your personal information. By agreeing to the Policy, you agree to our collection and use of your personal information as described in the Policy. This Privacy Policy is effective for all new users of Sanitaryplumbing.com.

2. Personal Information.

You can browse some areas of Antler.nyc (“the Website”) without being a registered user. However, certain activities do require registration. (You consent to the transfer and storage of your information by registering with Antler.nyc). We may collect and store the following personal information:

  • Name, email, address, telephone number, and (depending on the service used), move-in dates;
  • Transactional information (such as lease terms, lease parties);
  • Computer sign-on data, statistics on page views, and traffic to and from the Website; and
  • Other information, including IP address and other web log information.

3. Use of Information.

Our primary purpose in collecting personal information is to provide you with a safe and user-friendly experience. For example, the Company may use your personal information to:

  • Improve our services and the Website’s content and layout;
  • Provide the services and necessary customer support you request;
  • Resolve disputes, collect fees, and troubleshoot problems;
  • Track and record customer satisfaction with our services;
  • Protect the Company against error and fraud;
  • Inform you of special promotions and announcements;
  • Enforce our agreements, terms, conditions, and policies; and
  • As otherwise described to you at the time of collection.

We may occasionally ask you to complete optional surveys. These surveys are used to improve and customize your experience with Sanitaryplumbing.com.

The Company always provides you the ability to opt-out of further communication such as promotions and surveys; see the Opt-Out section below.

The Company does not share any of your personal information with outside organizations, companies, individuals, etc. The only exception to this standard is if such a disclosure is reasonably necessary to respond to any and all legal processes.

4. Links to Other Sites.

The Website may have links to other websites that may collect personally identifiable information about you. The Company is not responsible for the privacy practices of the content of those linked websites.

5. Safety & Security Precautions.

The Website has strict security measures in place to protect you and your information from fraud. Once your information is provided to Antler Pump & Motor Corporation, we strive to ensure the confidentiality of your identity and information.

6. Opt-Out.

The Company provides you with the opportunity to opt-out of receiving promotional and other non-essential, marketing-related communications from Antler Pump & Motor Corporation. If you would like to opt-out of these select communications, please see any of the Company’s email communications and follow the directions indicated.

7. Account Protection.

Your password ensures the security of your account. When choosing a password, the Company suggests using various characters. It is highly recommended that you do not disclose your Sanitaryplumbing.com password to anyone. (If you do disclose your password or your personal information with others, you are responsible for all actions taken in the name of your account.) If the security of your password is compromised for any reason, please contact the Company immediately.

8. Accuracy of Information

The Company does not guarantee the accuracy of information for any and all of its properties on the Website, and is not responsible for any errors or misrepresentations (made by Renters, the Client, or otherwise).

9. Cookies

The Company may place a small cookie on your computer’s hard drive. This allows us to personalize your use on the Website. In order to maximize the functionality and usability of the Website, you must set your browser’s preferences to allow both permanent and temporary cookies.

10. Changing Your Personal Information.

Should your personal information change, please immediately update your information on the Website. This will ensure the accuracy of our records. The Company does retain personal information from closed accounts in order to comply with law and collect and disburse any fees owed.

11. Third Parties

This Privacy Policy addresses only the use of information we collect from you. Since Antler.nyc does not control the privacy policies of third parties, you are subject to the privacy policies of those third parties. It is advisable that you consult with the management of third parties before you disclose your personal information to others.

12. General

We may amend this Privacy Policy at any time by posting the amended terms on the Website. All amended terms are immediately effective after they are initially posted on the Website.

13. Privacy Policy Questions & Concerns

Questions and/or concerns regarding the Policy should be emailed to the following email address: info@antler.nyc.